Types of volumetric multi-functional heat exchangers:
-
Volumetric multi-functional heat exchangers with one copper coil pipe
-
Volumetric multi-functional heat exchangers with two copper coil pipes
-
Volumetric multi-functional heat exchangers with three copper coil pipes
-
Volumetric multi-functional accumulation tanks
-
Volumetric multi-functional heat exchangers with an additional internal tank
-
Volumetric multi-functional heat exchangers of a tank-in-tank type with one copper coil pipe
-
Volumetric multi-functional heat exchangers of a tank-in-tank type with two copper coil pipes
1. Volumetric multi-functional heat exchangers with one copper coil pipe:
- Family of tanks with one domestic hot water copper coil pipe, including the option to install an electrical heater
- Capacity of tanks: from 100 to 1200 litres
- Additional connection orifices as an option
- For solid-fuel boilers, heat pumps and fireplaces with the power of up to 10 Kw
 |
1 – return from a boiler 2”
2 – solar collector outlet 1 ”
3 – solar collector inlet 1 ”
4 – solar collector sensor ½”
5 – return from a CHS 1”
6 – return from a CHS 1”
7 – return from a CHS 1”
8
– heater 2”
9
– sensor ½”
10 – outlet to a CHS 1”
11 – outlet to a CHS 1”
12 – inlet from a boiler 2”
13 – outlet to a CHS 1”
14 – domestic cold water inlet Ø15
16 – drain valve ¾”
17 – thermometer ½”
18 – thermometer ½”
|

|
|
| model |
Capacity
liters |
Diameter mm |
Height mm |
Weight kg |
Heating power of heating equipment Kw |
100/1W |
100 |
480 |
1200 |
67 |
do 10 |
200/1W |
220 |
480 |
1950 |
100 |
10-15 |
400/1W |
400 |
650 |
1950 |
120 |
15-20 |
700/1W |
670 |
770 |
1950 |
170 |
20-25 |
900/1W |
870 |
900 |
2100 |
200 |
30-50 |
1200/1W |
1170 |
1000 |
2200 |
220 |
Up to 50 |
2. Volumetric multi-functional heat exchangers with two coil pipes
- Family of tanks with two copper coil pipes for domestic hot water system and solar collectors, including the option to install an electrical heater
- They operate both as a heat accumulator, a constant-flow feedwater heater and a heat coupling – thus allowing for connection of several sources of heat to a number of central heating systems and hot tap water systems
- Capacity of tanks: from 200 to 1200 litres
 |
1 – inlet from a boiler
2 –solar collector outlet
3 – solar collector inlet
4 – solar collector sensor ½”
5 – return from a CHS 1”
6 – return from a CHS 1”
7 – return from a CHS 1”
8- outlet to a gas-fired stove 1”
8a- return from a gas-fired stove 1”
9 – heater 2”
10 – sensor ½”
11 – outlet to a CHS 1”
12 – outlet to a CHS 1”
13 – outlet to a CHS 1”
14 – inlet from a boiler
15 – domestic cold water inlet Ø15
16 – drain valve ¾”
17 – thermometer ½”
18 – thermometer ½” |
 |
|

|
|
| model |
Capacity
liters |
Diameter mm |
Height mm |
Weight kg |
Heating power of heating equipment Kw |
200/2W |
200 |
480 |
1950 |
120 |
10-15 |
400/2W |
420 |
650 |
1950 |
140 |
15-20 |
700/2W |
640 |
770 |
1950 |
170 |
20-25 |
900/2W |
850 |
900 |
2100 |
220 |
30-50 |
1200/2W |
1150 |
1000 |
2200 |
240 |
up to 50 |
3. Volumetric multi-functional heat exchangers with three coil pipes
- Family of tanks with three copper coil pipes, including the option to install an electrical heater.
- Application:
- one coil pipe to be connected to a central heating system
- one coil pipe to be connected to a solar collector system
- one coil pipe to be connected to a gas-fired stove
- Capacity of tanks: from 400 to 1200 litres
 |
1 – return to the boiler 6/4”
2 – solar collector outlet 1”
3 – solar collector inlet 1”
4 – space for a solar collector sensor ½”
5 – return from a CHS 1”
6 – return from a CHS 1”
8 – outlet to a gas-fired stove 1”
9 – return from a gas-fired stove 1”
10 – sensor ½”
11 – return from a CHS 1”
12 – outlet to a CHS 1”
13 – outlet to a CHS 1”
14 –inlet from a boiler 6/4”
15 – domestic cold water inlet 1/2”
16 – drain valve ¾”
17 – thermometer ½”
18 – thermometer ½” |
 |
|
| model |
Capacity
liters |
Diameter mm |
Height mm |
Weight kg |
Heating power of heating equipment Kw |
400/3W |
350 |
650 |
1950 |
160 |
15-20 |
700/3W |
600 |
770 |
1950 |
190 |
20-25 |
900/3W |
830 |
900 |
2100 |
240 |
30-50 |
1200/3W |
1130 |
1000 |
2200 |
260 |
up to 50 |
4. Volumetric multi-functional heat exchangers used as an accumulation tank
- Family of accumulation tanks with the tank capacity from 700 to 1200 litres
- The accumulation tank accumulates and then distributes the heat generated by a solid-fuel boiler, solar collectors, fireplaces with water jacket and heat pumps.
- The accumulation tank ensures the optimum boiler temperature of 80-90ºC
- It also ensures quick heating up of a boiler to its normal working temperature
 |
1 – return to a boiler 2”
4 – return from a CHS 1”
5 – return from a CHS 1”
6 – return from a CHS 1”
9 – space for a sensor ½”
10 – outlet to a CHS 1”
11 – outlet to a CHS 1”
12 – outllet to a CHS 1”
13 – inlet from a boiler 2”
16 – drain valve ¾”
17 – thermometer ½”
18 – thermometer ½” |
| model |
Capacity
liters |
Diameter mm |
Height mm |
Weight kg |
Heating power of heating equipment Kw |
700 |
700 |
650 |
1950 |
150 |
20-25 |
900 |
900 |
900 |
2100 |
170 |
30-50 |
1200 |
1000 |
1000 |
2200 |
200 |
up to 50 |
5. Volumetric multi-functional heat exchangers of a tank-in-tank type
- Volumetric multi-functional heat exchanger with a 200-liter domestic hot water reservoir
- Made of stainless steel, external walls covered with anticorrosive paint
- Anodic protection is not required
- No accumulation of boiler scale
- Large heating surface
- Water heats up quickly
- Low heat loss
- Storing water in high temperature (60 to 80ºC) prevents Legionella development
- Sources of heat for the heating water: solar collector system, heat pumps, solid-fuel boilers, electric heater, etc.
 |
1 – return to a boiler 2”
2 – return from a CHS 1”
3 – return from a CHS 1”
4 – return from a CHS 1”
5- heater 2”
6 – space for a sensor ½”
7 – outlet to a CHS 1”
8 – outlet to a CHS 1”
9 – inlet from a boiler 2”
10 – outlet to a CHS 1”
11 – drain valve ¾”
12 – thermometer ½”
13- drain ½’
14 – thermometer ½” |
| model |
Capacity
liters |
Diameter mm |
Height mm |
Weight kg |
Heating power of heating equipment Kw |
500/200N |
500/200 |
770 |
1950 |
180 |
do 30 |
700/200N |
700/200 |
900 |
2100 |
200 |
30-50 |
1000/200N |
1000/200 |
1000 |
2200 |
230 |
up to 50 |
6. Volumetric multi-functional heat exchangers of a tank-in-tank type with one copper coil pipe
- Volumetric multi-functional heat exchanger with a 200-liter domestic hot water reservoir with one copper coil pipe
- Made of stainless steel, external walls covered with anticorrosive paint
- Anodic protection is not required
- No accumulation of boiler scale
- Large heating surface
- Water heats up quickly
- Low heat loss
- Storing water in high temperature (60 to 80ºC) prevents Legionella development
- Sources of heat for the heating water: solar collector system, heat pumps, solid-fuel boilers, electric heater, etc.
 |
1 – return to a boiler 2”
2 – solar collector outlet 1”
3 – solar collector inlet 1”
4- space for a solar collector sensor ½”
5 – return from a CHS 1”
6 – return from a CHS 1”
7 – return from a CHS 1”
8 – space for a sensor ½”
9 – outlet to a CHS 1”
10 – outlet to a CHS 1”
11 – inlet from a boiler 2”
12 – outlet to a CHS 1”
13 – drain valve ¾”
14- drain ½’
15,16 – thermometer ½”
|
| model |
Capacity
liters |
Diameter mm |
Height mm |
Weight kg |
Heating power of heating equipment Kw |
500/200N/1W |
480/200 |
770 |
1950 |
200 |
do 30 |
700/200N/1W |
680/200 |
900 |
2100 |
220 |
30-50 |
1000/200N/1W |
980/200 |
1000 |
2200 |
250 |
up to 50 |
7. Volumetric multi-functional heat exchangers of a tank-in-tank type with two copper coil pipes
- Volumetric multi-functional heat exchanger with a 200-liter domestic hot water reservoir with two copper coil pipes
- Made of stainless steel, external walls covered with anticorrosive paint
- Anodic protection is not required
- No accumulation of boiler scale
- Large heating surface
- Water heats up quickly
- Low heat loss
- Storing water in high temperature (60 to 80ºC) prevents Legionella development
- Sources of heat for the heating water: solar collector system, heat pumps, solid-fuel boilers, electric heater, etc.
 |
1 – return to a boiler 2”
2 – return from a CHS 1”
3 – return from a CHS 1”
4 – return from a CHS 1”
5 – copper coil outlet 1”
6 – copper coil inlet 1”
7 – space for a sensor ½”
8 –copper coil outlet 1”
9 – copper coil inlet 1”
10 –inlet from a boiler 2”
10a –space for a sensor 1/2”
11 – outlet to a CHS 1”
12 –drain valve ¾”
13- drain ½’
14,15 – thermometer ½”
|

|
|
| model |
Capacity
liters |
Diameter mm |
Height mm |
Weight kg |
Heating power of heating equipment Kw |
500/200N/2W |
460/200 |
770 |
1950 |
220 |
do 30 |
700/200N/2W |
660/200 |
900 |
2100 |
240 |
30-50 |
1000/200N/2W |
960/200 |
1000 |
2200 |
270 |
up to 50 |
Technical parameters:
| - Material |
S235JR |
 |
| - Domestic hot water pressure |
6 bar |
| - Heat exchanger working pressure |
3 bar |
| - Maximum allowable working temperature |
95ºC |
| - Insulation |
Polyurethane foam |
| - Insulation external jacket |
Artificial leather |
- Heat transfer surface area of the domestic hot water copper coil pipe |
F= 2,35 m² |
| - Heating power of the domestic hot water copper coil pipe |
60kW |
| - Domestic hot water throughput |
960 l/h |
| - Heat transfer surface area of the solar collector coil pipe |
F=1,7m² |
| - Heating power of the solar collector copper coil pipe |
43 kW |
- Heat transfer surface area of the gas-fired stove copper coil pipe |
F=1,7 m² |
| - Heating power of the gas-fired stove copper coil pipe |
43 kW |
| - Guarantee |
10-year guarantee |
| - Closed or open circuit type heat exchangers |
|
| |
|
Technical parameters:
| - Material |
S235JR |
 |
| - Domestic hot water pressure |
6 bar |
| - Heat exchanger working pressure |
3 bar |
| - Maximum allowable working temperature |
95ºC |
| - Insulation |
Polyurethane foam |
| - Insulation external jacket |
Artificial leather |
- Heat transfer surface area of the domestic hot water
copper coil pipe |
F= 2,35 m² |
| - Heating power of the domestic hot water copper coil pipe |
60kW |
| - Domestic hot water throughput |
960 l/h |
| - Heat transfer surface area of the solar collector coil pipe |
F=1,7m² |
| - Heating power of the solar collector copper coil pipe |
43 kW |
- Heat transfer surface area of the gas-fired stove copper
coil pipe |
F=1,7 m² |
| - Heating power of the gas-fired stove copper coil pipe |
43 kW |
| - Guarantee |
2-year guarantee |
| - Closed or open circuit type heat exchangers |
|
| |
|
|